Resol DeltaSol SLL Controller comes with 10 pre-programmed system layouts and covers all necessary functions required in the solar thermal systems. Hardware consists of 4 temperature inputs, 2 semiconductor relay outputs, 1 dry contact output, 2 PWM outputs for ECM pumps and 1 RESOL Vbus terminal for any RESOL Vbus data transfer/storage device. The central LED button indicates different operation statuses: normal operation, faulty, holiday mode or manual mode.
Technical Data Overview:
| Max.# of collector fields: | 2 |
| Max. number of stores: | 2 |
| External heat exchanger: | No |
| Speed control of standard pumps: | Yes |
| Speed control of HE pumps: | Yes |
| Temperature sensor inputs: | 4 |
| Sensor type: | PT1000,PT500, KTY |
| Grundfos Direct Sensors™: | No |
| CS10 irradiation sensor: | No |
| Impulse inputs | 1 |
| semiconductor relays: | 2 |
| Dry Contact Relays: | 1 |
| PWM outputs: | 2 |
| 0-10V output: | 0 |
| Real-time clock: | Yes |
| Data interface: | Yes |
| Antifreeze function for solar circuit: | Yes |
| Collector minimum limitation: | Yes |
| Collector emergency shutdown: | Yes |
| Store maximum limitation: | Yes |
| Store Emergency Shutdown: | Yes |
| Drainback Option: | Yes |
| Tube collector function: | Yes |
| Additional ΔT control: | Yes |
| Thermostat function: | Yes |
| Heat dump function: | Yes |
| Heat exchange: | Yes |
| Priority loading: | Yes |
| Solar circuit bypass: | No |
| Back-up heating suppression: | No |
| Parallel relay: | Yes |
| Twin pump for solar circuit: | No |
| Cooling functions and cooling mode: | Yes |
| Flow rate monitoring: | No |
| Pressure monitoring: | No |
| Error relay: | No |
| DHW hygiene functions: | Yes |
| DHW heating: | Yes |
| Heating circuit return preheating: | Yes |
| Boiler loading/Zone loading: | No |
| Solid fuel boiler: | Yes |